Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • Sistem İçeriği
  • Analiz
  • Talep/Soru
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Gulbay, Mutlu" seçeneğine göre listele

Listeleniyor 1 - 1 / 1
Sayfa Başına Sonuç
Sıralama seçenekleri
  • Küçük Resim Yok
    Öğe
    A CT Radiomics Analysis of the Adrenal Masses: Can We Discriminate Lipid-poor Adenomas from the Pheochromocytoma and Malignant Masses?
    (Bentham Science Publ Ltd, 2023) Mendi, Bokebatur Ahmet Rasit; Gulbay, Mutlu
    Aims: The aim of the study is to demonstrate a non-invasive alternative method to aid the decision making process in the management of adrenal masses. Background: Lipid-poor adenomas constitute 30% of all adrenal adenomas. When discovered incidentally, additional dynamic adrenal examinations are required to differentiate them from an adrenal malignancy or pheochromocytoma. Objective: In this retrospective study, we aimed to discriminate lipid-poor adenomas from other lipid-poor adrenal masses by using radiomics analysis in single contrast phase CT scans. Materials and Methods: A total of 38 histologically proven lipid-poor adenomas (Group 1) and 38 cases of pheochromocytoma or malignant adrenal mass (Group 2) were included in this retrospective study. Lesions were segmented volumetrically by two independent authors, and a total of 63 sizes, shapes, and first- and second-order parameters were calculated. Among these parameters, a logit-fit model was produced by using 6 parameters selected by the LASSO (least absolute shrinkage and selection operator) regression. The model was cross-validated with LOOCV (leave-one-out cross-validation) and 1000-bootstrap sampling. A random forest model was also generated in order to use all parameters without the risk of multicollinearity. This model was examined with the nested cross-validation method. Results: Sensitivity, specificity, accuracy and AUC were calculated in test sets as 84.2%, 81.6%, 82.9% and 0.829 in the logit fit model and 91%, 80%, 82.8% and 0.975 in the RF model, respectively. Conclusion: Predictive models based on radiomics analysis using single-phase contrast-enhanced CT can help characterize adrenal lesions.

| Niğde Ömer Halisdemir Üniversitesi | Kütüphane | Açık Erişim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Merkez Yerleşke Bor Yolu 51240, Niğde, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim