Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • Sistem İçeriği
  • Analiz
  • Talep/Soru
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Halkaci, Huseyin Selcuk" seçeneğine göre listele

Listeleniyor 1 - 3 / 3
Sayfa Başına Sonuç
Sıralama seçenekleri
  • Küçük Resim Yok
    Öğe
    EFFECT OF SHEET THICKNESS ON THE ANISOTROPY AND THICKNESS DISTRIBUTION FOR AA2024-T4
    (INST ZA KOVINSKE MATERIALE I IN TEHNOLOGIE, 2013) Dilmec, Murat; Halkaci, Huseyin Selcuk; Ozturk, Fahrettin; Turkoz, Mevlut
    In this study, the effect of sheet thickness on the anisotropy and thickness distribution at room temperature (RT) was investigated for AA2024-T4 sheets. The anisotropy was determined using automated strain measurement with a grid analysis and profile-projector methods. The results indicate that the effects of the thicknesses of 0.8 mm, 1 mm, and 2 mm on the anisotropy were insignificant. In addition to the anisotropy measurement, the thickness variation of the specimens was also monitored. Besides the anisotropy values, no significant differences were observed between various thicknesses and directions.
  • Küçük Resim Yok
    Öğe
    Effect of sheet thickness on the anisotropy and thickness distribution for AA2024-T4
    (2013) Dilmec, Murat; Halkaci, Huseyin Selcuk; Ozturk, Fahrettin; Turkoz, Mevlut
    In this study, the effect of sheet thickness on the anisotropy and thickness distribution at room temperature (RT) was investigated for AA2024-T4 sheets. The anisotropy was determined using automated strain measurement with a grid analysis and profile-projector methods. The results indicate that the effects of the thicknesses of 0.8 mm, 1 mm, and 2 mm on the anisotropy were insignificant. In addition to the anisotropy measurement, the thickness variation of the specimens was also monitored. Besides the anisotropy values, no significant differences were observed between various thicknesses and directions.
  • Küçük Resim Yok
    Öğe
    INVESTIGATION INTO REASONS FOR MINIMUM MAJOR STRAIN OFFSETTING OF FORMING LIMIT CURVE OBTAINED WITH NAKAJIMA TEST FOR AA 2024-T4
    (GAZI UNIV, FAC ENGINEERING ARCHITECTURE, 2014) Dilmec, Murat; Halkaci, Huseyin Selcuk; Ozturk, Fahrettin
    In a typical forming limit curve (FLC), the minimum major strain where the minor value is equal to zero is located at y axes. In many forming processes, failure occurs at this region. Many studies in literature indicates that minimum major strain value is obtained about at y axis. In this study, the minimum major strain value is not determined on the y axes and it was found to be offsetted from the y axes to the right about 0.04 strain for AA 2024-T4. This value could be important for evaluations of sheet metal forming processes. In this study, the reasons for the minimum major strain of setting of the forming limit curve for AA 2024-T4 were investigated. It was found that drawbead and heat treatment were most effective parameters for this offsetting. It is observed that offsetting result from pre-strain which occur for conducted tests with using draw-bead and residual stress arising from T4 heat treatment.

| Niğde Ömer Halisdemir Üniversitesi | Kütüphane | Açık Erişim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Merkez Yerleşke Bor Yolu 51240, Niğde, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim