Yazar "Jaworski, G." seçeneğine göre listele
Listeleniyor 1 - 3 / 3
Sayfa Başına Sonuç
Sıralama seçenekleri
Öğe Digital pulse-timing technique for the neutron detector array NEDA(ELSEVIER SCIENCE BV, 2015) Modamio, V.; Valiente-Dobon, J. J.; Jaworski, G.; Hueyuek, T.; Triossi, A.; Egea, J.; Gadea, A.A new digital pulse-timing algorithm, to be used with the future neutron detector array NEDA, has been developed and tested. The time resolution of four 5 in diameter photomultiplier tubes (XP4512, R4144, R11833-100, and ET9390-kb), coupled to a cylindrical 5 in by 5 in BC501A liquict scintillator detector was measured by employing digital sampling electronics and a constant fraction discriminator (CFD) algorithm. The zero crossing of the CM algorithm was obtained with a cubic spline interpolation, which was continuous up to the second derivative. The performance of the algorithm was studied at sampling rates of 500 MS/s and 200 MS/s. The time resolution obtained with the digital electronics was compared to the values acquired with a standard analog CFD. The result of this comparison shows that the time resolution from the analog and the digital measurements at 500 MS/s and at 200 MS/s are within 15% for all the tested photomultiplier tubes. (C) 2014 Elsevier B.V. All rights reserved.Öğe Lifetimes of core-excited states in semi-magic 95Rh(Springer, 2020) Ertoprak, A.; Qi, C.; Cederwall, B.; Doncel, M.; Jakobsson, U.; Nyako, B. M.; Jaworski, G.Lifetimes of negative-parity states have been determined in the neutron deficient semi-magic (N = 50) nucleus Rh-95. The fusion-evaporation reaction Ni-58(Ca-40, 3p) was used to populate high-spin states in Rh-95 at the Grand Accelerateur National d'Ions Lourds (GANIL) accelerator facility. The results were obtained using the Doppler Shift Attenuation Method (DSAM) based on the Doppler broadened line shapes produced during the slowing down process of the residual nuclei in a thick 6 mg/cm(2) metallic target. B(M1) and B(E2) reduced transition strengths are compared with predictions from large-scale shell-model calculations. state-of-the-art theory. Remarkably, the structural features up to moderate angular momentum of nuclei immediately below the N = Z = 50 shell closures can be described with high accuracy in a very simple way by shell-model calculations including only the g(9/2) and p(1/2) subshells. Of special interest is the neutron-proton pair coupling scheme which is expected to appear in the heaviest N=Z nuclei [1,2] and the seniority structure of the N = 50 isotones [3-7]. However, multiple core-excited states have been observed in the semi-magic nuclei of the Sn-100 region [8-10]. The theoretical study of those states is a challenging task, which requires a significantly larger model space for their interpretation. Transition probabilities between nuclear states provide important constraints for theoretical modelling of the structure of the nuclei of interest. Our previous lifetime study of the semimagic (N = 50) nucleus Ru-94 [ 11,12] provided information on the electromagnetic decay properties of neutron-core excited states. We now address lifetime measurements in its closest, more neutron deficient, isotone Rh-95 using the same DSAM technique. The experimental results have been interpreted within the framework of large-scale shell-model (LSSM) calculations.Öğe Monte Carlo simulation of a single detector unit for the neutron detector array NEDA(ELSEVIER SCIENCE BV, 2012) Jaworski, G.; Palacz, M.; Nyberg, J.; de Angelis, G.; de France, G.; Di Nitto, A.; Hueyuek, T.A study of the dimensions and performance of a single detector of the future neutron detector array NEDA was performed by means of Monte Carlo simulations, using GEANT4. Two different liquid scintillators were evaluated: the hydrogen based BC501A and the deuterated BC537. The efficiency and the probability that one neutron will trigger a signal in more than one detector were investigated as a function of the detector size. The simulations were validated comparing the results to experimental measurements performed with two existing neutron detectors, with different geometries, based on the liquid scintillator BC501. (C) 2012 Elsevier B.V. All rights reserved.