    Microstructural examination of the effect of elevated temperature on the concrete containing clinoptilolite
    (ELSEVIER SCI LTD, 2014) Akcaozoglu, Kubilay; Fener, Mustafa; Akcaozoglu, Semiha; Ocal, Recep
    In this study, the effect of elevated temperature on the properties of concrete containing clinoptilolite was investigated by microscopic analyses. For this purpose, seven different mixtures were prepared (the control mixture and six mixtures including 5%, 10%, 15%, 20%, 30% and 40% clinoptilolite by weight). The water binder (w/b) ratio used in the mixtures was 0.475. The dry unit weights, water absorption ratios, porosity ratios, compressive strengths and thermal conductivity coefficients of the mixtures were measured. In addition the specimens exposed to elevated temperatures of 250, 500,750 and 1000 degrees C. Two different cooling methods were used (slow cooling and fast cooling). The residual compressive strengths of the specimens which were exposed to elevated temperatures were measured. In addition the mineral and texture changes of the specimens were examined by using plane polarized microscope. Test results indicated that, clinoptilolite substitution decreased the compressive strength of the specimens in early days, but increased at later days. The positive effects were observed about clinoptilolite substitution on the residual compressive strength of the specimens. It was observed from microscopic analyses that, as the amount of clinoptilolite increased in the mixtures, aggregates were less affected from elevated temperatures. Fast cooling (FC) method resulted in strength losses when compared to slow cooling (SC) method. Additionally, clinoptilolite substitution decreased the thermal conductivity coefficient of the concrete. (C) 2014 Elsevier Ltd. All rights reserved.

| Niğde Ömer Halisdemir Üniversitesi | Kütüphane | Açık Erişim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Merkez Yerleşke Bor Yolu 51240, Niğde, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim