Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • Sistem İçeriği
  • Analiz
  • Talep/Soru
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Ozmen, S. F." seçeneğine göre listele

Listeleniyor 1 - 2 / 2
Sayfa Başına Sonuç
Sıralama seçenekleri
  • Küçük Resim Yok
    Öğe
    Photonuclear reactions induced by a clinical linac
    (IOP PUBLISHING LTD, 2015) Boztosun, I.; Dapo, H.; Karakoc, M.; Ozmen, S. F.; Cecen, Y.; Coban, A.; Kucuk, Y.
    The use of a clinical linac in photonuclear experiments is a novel concept. At Akdeniz University a program has been started focused on inducing photonuclear reactions with a Philips SLI-25 clinical linac. A bremsstrahlung photon beam produced by the linac is used to create radioactive nuclei. The decay of said nuclei is observed with a high-purity germanium detector. During the course of the experiment the spectrum of the irradiated sample is recorded. By analyzing the spectrum the energies of gamma-ray transitions in the daughter nuclei as well as the half-life of the parent nucleus are obtained. The results obtained thus far, starting with Zinc nuclei will be presented.
  • Küçük Resim Yok
    Öğe
    Photonuclear reactions with zinc: A case for clinical linacs
    (SPRINGER HEIDELBERG, 2015) Boztosun, I.; Dapo, H.; Karakoc, M.; Ozmen, S. F.; Cecen, Y.; Coban, A.; Harakeh, M. N.
    The use of bremsstrahlung photons produced by a linac to induce photonuclear reactions is wide spread. However, using a clinical linac to produce the photons is a new concept. We aimed to induce photonuclear reactions on zinc isotopes and measure the subsequent transition energies and half-lives. For this purpose, a bremsstrahlung photon beam of 18 MeV endpoint energy produced by the Philips SLI-25 linac has been used. The subsequent decay has been measured with a well-shielded single HPGe detector. The results obtained for transition energies are in good agreement with the literature data and in many cases surpass these in accuracy. For the half-lives, we are in agreement with the literature data, but do not achieve their precision. The obtained accuracy for the transition energies show what is achievable in an experiment such as ours. We demonstrate the usefulness and benefits of employing clinical linacs for nuclear physics experiments.

| Niğde Ömer Halisdemir Üniversitesi | Kütüphane | Açık Erişim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Merkez Yerleşke Bor Yolu 51240, Niğde, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim