Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • Sistem İçeriği
  • Analiz
  • Talep/Soru
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Ozturk, Merve" seçeneğine göre listele

Listeleniyor 1 - 1 / 1
Sayfa Başına Sonuç
Sıralama seçenekleri
  • Küçük Resim Yok
    Öğe
    A Critical Study on the Potential of Solid-Phase Fluorescence Spectroscopy (SPFS) in Quantitative Analysis: Effect of Solid Diluent and Sampling Method on Signal Quality
    (Oxford Univ Press Inc, 2023) Ozturk, Merve; Gezici, Orhan
    Background Solid-phase fluorescence spectroscopy (SPFS) is a very useful non-destructive technique for directly analyzing samples in solid form without the use of solvents. However, due to the so-called inner-filter effect, it is sometimes necessary to dilute solid samples using non-fluorescent solids as diluents. Objective This study aimed to explore the potential of SPFS in the quantitative analysis of fluorescent species based on: (1) the type of solid diluent; and (2) the sampling method used in the SPFS analysis. Methods Four different solids were used as solid diluents in the preparation of standard mixtures having different concentrations of rhodamine b and fluorescein as model compounds. Standard mixtures of model compounds were sampled by two different methods called: (1) the powder-cell method; and (2) the adhesive tape method. LOQ and calibration sensitivity calculated from the calibration graphs were used to assess the measurement performance. The usability of SPFS in real-sample analyses was also evaluated in detail. Results Among the solid diluents studied, the best results were obtained with sodium carbonate. The powder-cell method yielded a significant advantage over the adhesive tape method. The lowest LOQs for rhodamine b and fluorescein were obtained by sodium carbonate and the powder-cell method as 0.06 mg/kg and 0.11 mg/kg, respectively. The results of real-sample analyses were verified using conventional liquid-phase fluorescence spectroscopy (LPFS). Conclusion Solid-diluent type and sampling method were found to affect the performance of the SPFS technique. A combination of sodium carbonate and the powder-cell method gave the best results. According to the t-test, no difference was observed between the means obtained by SPFS and LPFS techniques in real-sample analyses.

| Niğde Ömer Halisdemir Üniversitesi | Kütüphane | Açık Erişim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Merkez Yerleşke Bor Yolu 51240, Niğde, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim