Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • Sistem İçeriği
  • Analiz
  • Talep/Soru
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Soylak, M." seçeneğine göre listele

Listeleniyor 1 - 2 / 2
Sayfa Başına Sonuç
Sıralama seçenekleri
  • Küçük Resim Yok
    Öğe
    A NEW CLOUD POINT EXTRACTION PROCEDURE FOR DETERMINATION OF TRACE AMOUNT CRYSTAL VIOLET IN WASTEWATER BY UV-VIS. SPECTROMETRY
    (SCIBULCOM LTD, 2015) Bisgin, A. T.; Narin, I.; Ucan, M.; Soylak, M.
    A new cloud point extraction procedure was developed as surfactant using mixed micelles of Tween-80 and Tergitol TMN-6 for separation and preconcentration of crystal violet in aqueous media. To determine the optimum conditions, the effects of analytical parameters such as pH, mixed ratio of surfactants, amount of mixed surfactants, the equilibrium temperature and time, centrifugation time and rates, and matrix effect of some ions were studied. Linear calibration curve (range from 2 to 400 ng ml(-1)) was obtained after applying developed cloud point extraction procedure. Crystal violet content of some waste water and lake water samples was determined after using developed method by UV-vis. spectrometry at 600 nm.
  • Küçük Resim Yok
    Öğe
    A new cloud point extraction procedure for determination of trace amount crystal violet in wastewater by UV-VIS. Spectrometry
    (Scibulcom Ltd., 2015) Bisgin, A.T.; Narin, I.; Ucan, M.; Soylak, M.
    A new cloud point extraction procedure was developed as surfactant using mixed micelles of Tween-80 and Tergitol TMN-6 for separation and preconcentration of crystal violet in aqueous media. To determine the optimum conditions, the effects of analytical parameters such as pH, mixed ratio of surfactants, amount of mixed surfactants, the equilibrium temperature and time, centrifugation time and rates, and matrix effect of some ions were studied. Linear calibration curve (range from 2 to 400 ng ml–1) was obtained after applying developed cloud point extraction procedure. Crystal violet content of some waste water and lake water samples was determined after using developed method by UV-vis. spectrometry at 600 nm. © 2015, Scibulcom Ltd. All rights reserved.

| Niğde Ömer Halisdemir Üniversitesi | Kütüphane | Açık Erişim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Merkez Yerleşke Bor Yolu 51240, Niğde, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim