Power flattening in the fuel bundle of a CANDU reactor

Küçük Resim Yok

Tarih

2004

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

ELSEVIER SCIENCE SA

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Özet

The strong non-uniformity of the fission power production density in the CANDU fuel bundle could have been mitigated to a great degree. A satisfactory power flattening has been achieved through an appropriately evaluated method by varying the composition of the LWR spent fuel/ThO2 Mixture in a CANDU fuel bundle in radial direction and keeping fuel rod dimensions unchanged. This will help also to greatly simplify fuel rod fabrication and allow a higher degree of quality assurance standardization. Three different bundle fuel charges are investigated: (1) the reference case, uniformly fueled with natural UO2, (2) a bundle uniformly fueled with LWR spent fuel, and (3) a bundle fueled with variable mixed fuel composition in radial direction leading to a flat power profile (100% LWR spent fuel in the central rod, 80% LWR + 20% ThO2 in the second row, 60% LWR + 40% ThO2 in the third row and finally 40% LWR + 60% ThO2 in the peripheral fourth row). Burn-up grades for these three different bundle types are calculated as similar to7700, similar to27,300, and 10,000 MW.D/MT until reaching a lowest bundle criticality limit of k(infinity) = 1.06. The corresponding plant operation periods are 170, 660, and 240 days, respectively. (C) 2004 Elsevier B.V. All rights reserved.

Açıklama

Anahtar Kelimeler

Kaynak

NUCLEAR ENGINEERING AND DESIGN

WoS Q Değeri

Q3

Scopus Q Değeri

Q1

Cilt

232

Sayı

1

Künye