Eight-year follow-up of uncemented hydroxyapatite coated hip prosthesis for hip osteoarthritis secondary to developmental hip dysplasia [Gelişimsel kalça displazisi zemininde gelişen osteoartritli kalçalarda kullanilan çimentosuz hidroksiapatit kapli kalça protezlerinde sekiz yillik izlem]

dc.contributor.authorSarikaya B.
dc.contributor.authorAtaoglu B.
dc.contributor.authorGörmeli G.
dc.contributor.authorÖztürk B.Y.
dc.contributor.authorTuranli S.
dc.date.accessioned2019-08-01T13:38:39Z
dc.date.available2019-08-01T13:38:39Z
dc.date.issued2013
dc.departmentNiğde ÖHÜ
dc.description.abstractObjectives: This study aims to investigate the mid-term clinical and radiological results of cementless hydroxyapatite coated total hip arthroplasty (THA) for hip osteoarthritis due to developmental dysplasia of the hip (DDH). Patients and methods: Between January 2004 and December 2010, 34 hips (12 Crowe type I, 12 Crowe type II, 4 Crowe type III, 6 Crowe type IV) of 30 patients (22 females, 8 males; mean age 53.4 years; range 30 to 75 years) with degenerative arthritis due to DDH were analyzed in terms of cementless hydroxyapatite coated acetabular component (EPF Plus®) over Zweymüller femoral component (Zweymüller SL-PLUS®) and porous coating. Clinical assessment was performed using Harris hip scores (HHS) preoperatively and at the last clinic visit, while radiological assessment was done according to the Callaghan and Engh's criteria. Results: The mean follow-up was 48 months (range, 25-91 months). The mean HHS was 44.97 (28-55) preoperatively and 92.25 (69-100) at the last visit. All femoral components were graded as stable according to Callaghan and Engh's criteria. Radiolucency was mostly observed in Gruen zones 1 and zone 7 of the femur [zone 1; 20 hips zone 7; 19 hips zone 2; one hip, zone 3; one hip and zone 6 one hip]. Around acetabular component, radiolucency was detected in zone 2 in 12 hips, zone 3 in 10 hips and zone 1 in six hips. Heterotopic ossification developed in two hips, while neuropraxy was detected in two hips postoperatively. Femoral fissure in one hip, nonunion in the femoral osteotomy line in one hip, and femoral head autograft nonunion in one hip developed. Conclusion: Mid-term results of uncemented Zweymüller femoral stem and hydroxyapatite coated press-fit using acetabular components for THA femoral stem are excellent.
dc.identifier.doi10.5606/ehc.2013.21
dc.identifier.endpage95
dc.identifier.issn1305-8282
dc.identifier.issue2
dc.identifier.startpage91
dc.identifier.urihttps://dx.doi.org/10.5606/ehc.2013.21
dc.identifier.urihttps://hdl.handle.net/11480/826
dc.identifier.volume24
dc.institutionauthor[0-Belirlenecek]
dc.language.isotr
dc.relation.ispartofEklem Hastaliklari ve Cerrahisi
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectHydroxyapatite coated femoral stem
dc.subjectHydroxyapatite coated press-fit acetabular component
dc.subjectMid-term result
dc.subjectUncemented hip arthroplasty
dc.titleEight-year follow-up of uncemented hydroxyapatite coated hip prosthesis for hip osteoarthritis secondary to developmental hip dysplasia [Gelişimsel kalça displazisi zemininde gelişen osteoartritli kalçalarda kullanilan çimentosuz hidroksiapatit kapli kalça protezlerinde sekiz yillik izlem]
dc.typeArticle

Dosyalar