High-resolution imaging of biotite using focal series exit wavefunction restoration and the graphene mechanical exfoliation method

dc.contributor.authorBower W.
dc.contributor.authorHead W.
dc.contributor.authorDroop G.T.R.
dc.contributor.authorZan R.
dc.contributor.authorPattrick R.A.D.
dc.contributor.authorWincott P.
dc.contributor.authorHaigh S.J.
dc.date.accessioned2019-08-01T13:38:39Z
dc.date.available2019-08-01T13:38:39Z
dc.date.issued2015
dc.departmentNiğde ÖHÜ
dc.description.abstractWe have applied mechanical exfoliation for the preparation of ultra-thin samples of the phyllosilicate mineral biotite. We demonstrate that the 'scotch tape' approach, which was made famous as an early method for production of single-atom-thick graphene, can be used for production of sheet-silicate specimens that are sufficiently thin to allow high-resolution transmission electron microscope (HRTEM) imaging to be achieved successfully while also being free from the specimen preparation artefacts that are often caused by ion-beam milling techniques. Exfoliation of the biotite parallel to the (001) planes has produced layers as thin as two structural TOT units thick (~2 nm). The minimal specimen thickness enabled not only HRTEM imaging but also the application of subsequent exit wavefunction restoration to reveal the pristine biotite lattice. Exit wavefunction restoration recovers the full complex electron wave from a focal series of HRTEM images, removing the effects of coherent lens aberrations. This combination of methods therefore produces images in which the observed features are readily interpreted to obtain atomic resolution structural information. © 2015 Mineralogical Society 2015.
dc.identifier.doi10.1180/minmag.2015.079.2.11
dc.identifier.endpage344
dc.identifier.issn0026461X
dc.identifier.issue2
dc.identifier.scopus2-s2.0-84946055984
dc.identifier.scopusqualityN/A
dc.identifier.startpage337
dc.identifier.urihttps://dx.doi.org/10.1180/minmag.2015.079.2.11
dc.identifier.urihttps://hdl.handle.net/11480/1956
dc.identifier.volume79
dc.indekslendigikaynakScopus
dc.institutionauthor[0-Belirlenecek]
dc.language.isoen
dc.publisherMineralogical Society
dc.relation.ispartofMineralogical Magazine
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectBiotite
dc.subjectExfoliation
dc.subjectFocal series
dc.subjectGraphene
dc.subjectHigh-resolution transmission electron microscopy
dc.titleHigh-resolution imaging of biotite using focal series exit wavefunction restoration and the graphene mechanical exfoliation method
dc.typeArticle

Dosyalar