Influence of polyvinylpyrrolidone on rebar corrosion in sulphate solution

Küçük Resim Yok

Tarih

2009

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

TECHNO-PRESS

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Özet

This paper reports the results of an experimental investigation of the polyvinylpyrrolidone (PVP) influence on the steel reinforcement corrosion and compressive strength of concretes in sulphate medium. The effect of admixture of PVP in concrete on the corrosion resistance of steel reinforced concrete was assessed by measuring electrochemical test during 60 days immersion in two different external solutions. AC impedance spectrum indicated that the resistance of PVP mixed electrodes were higher than those without PVP. The compressive strength of concrete specimens containing PVP was measured and an increase of 190%similar to 24% was observed.

Açıklama

Anahtar Kelimeler

reinforcing steel, corrosion, polyvinylpyrrolidone, AC impedance, sulphate

Kaynak

STEEL AND COMPOSITE STRUCTURES

WoS Q Değeri

Q2

Scopus Q Değeri

Q1

Cilt

9

Sayı

1

Künye