Öğe Experimental and numerical investigation of forced convection in a double skin façade(MDPI AG, 2017) Inan T.; Basaran T.; Erek A.Flow and heat transfer of the air cavity between two glass façades designed in the box window type of double skin façade (DSF) was evaluated in a test room which was set up for measurements in the laboratory environment and analyzed under different working conditions by using a computational fluid dynamics tool. Using data from the experimental studies, the verification of the numerical studies was conducted and the air flow and heat transfer in the cavity between the two glass façades were examined numerically in detail. The depth to height of the cavity, the aspect ratio, was changed between 0.10 and 0.16, and was studied for three different flow velocities. Reynolds and average Nusselt numbers ranging from 28,000 to 56,500 and 134 to 272, respectively, were calculated and a non-dimensional correlation between Reynolds and Nusselt numbers was constructed to evaluate the heat transfer from the cavity (except inlet and outlet sections) air to the inside environment and it could be used the box window type of DSF applications having relatively short cavities. © 2017 by the authors. Licensee MDPI, Basel, Switzerland.Öğe Experimental and numerical investigation of forced convection in a double skin façade by using nodal network approach for Istanbul(Elsevier Ltd, 2019) Inan T.; Basaran T.In this study, temperature distribution and heat transfer through the cavity of a double skin façade (DSF) was investigated in the laboratory environment and analyzed numerically by using nodal network approach. The verification of the nodal network method was conducted by using data from the steady-state experiments and the same method was applied for the climate of Istanbul, Turkey under unsteady outside boundary conditions. Furthermore, heat gain and loss values in DSF for January and July were calculated and compared with single skin façade (SSF) application for different directions of the façades. The results were given for a day and a working time period of the office buildings by using monthly average daily climate data. Distinction working hours were more convenient to investigate the energy performance of DSF because of solar radiation effect. Using DSF in all directions, the cooling loads decreased up to 26% comparing to the SSF. DSF system was disadvantageous comparing to the SSF for January. However, it was shown that the heated air in the cavity could be used for preheating process of air in a HVAC system for winter period. © 2019