Comparison of Anatomical and Functional Outcomes of Viscoimplantation and Hydroimplantation Techniques in Foldable Intraocular Lens Implantation
Küçük Resim Yok
Tarih
2023
Yazarlar
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
Erişim Hakkı
info:eu-repo/semantics/openAccess
Özet
Objective: The aim of this study was to compare the anatomical and functional results of viscoimplantation and hydroimplantation techniques in monofocal foldable intraocular lens implantation. Materials and Methods: The study included 387 patients older than 50 years who underwent surgery for senile cataract. They were divided into two subgroups as hydroimplantation (group 1) and viscoimplantation (group 2). Results: The mean implantation time was 397.5±44.3 s in group 1 and 580±105.1 s in group 2. During the follow-up period (12 months), 4 (2.1%) patients in group 1 and 28 (14.6%) patients in group 2 developed posterior capsular opacification. The implantation time was shorter and the rate of posterior capsular opacification was lower in group 1 compared to group 2 (p
Açıklama
Anahtar Kelimeler
Tıbbi Araştırmalar Deneysel, Mikrobiyoloji, Göz Hastalıkları, Tıbbi Laboratuar Teknolojisi, Cataract, Hydroimplantation, Intraocular Lens, Viscoimplantation
Kaynak
Çukurova Anestezi ve Cerrahi Bilimler Dergisi
WoS Q Değeri
Scopus Q Değeri
Cilt
6
Sayı
3