The Determination of Deteriorations on The Misirlioglu Bridge (Konya, Turkey) by Non-Destructive Techniques (NDT)

dc.contributor.authorTosunlar, Mehmet Bahadir
dc.contributor.authorHatir, Mehmet Ergun
dc.contributor.authorInce, Ismail
dc.contributor.authorBozdag, Ali
dc.contributor.authorKorkanc, Mustafa
dc.date.accessioned2024-11-07T13:31:48Z
dc.date.available2024-11-07T13:31:48Z
dc.date.issued2018
dc.departmentNiğde Ömer Halisdemir Üniversitesi
dc.description.abstractTransportation has been one of the basic requirements of humanity since the earliest periods of civilization. One of the architectural structures designed to meet this requirement is historic stone bridges. One of the most important stages in these conservation works is the assessment of materials that constitute the structures. Non-destructive testing techniques (NDT) are widely used to obtain qualitative data and also make comparisons. In this study, it was aimed to determine deteriorations on the Misirlioglu Bridge located in Sille settlement of Konya by NDT technique and to form the map from obtained values to perform conservation works. As a result of the analyses performed, considerable deteriorations in the building stones used in the abutments and arches of the structure were determined. Besides, it is detected that uniaxial compressive strength (UCS) value of the fresh samples is high (UCS: 61 MPa) while UCS values of the building stones used at the bridge decrease in the range of low and high (8-51 MPa) due to the atmospheric effects.
dc.identifier.doi10.15320/ICONARP.2018.60
dc.identifier.endpage412
dc.identifier.issn2147-9380
dc.identifier.issue2
dc.identifier.startpage399
dc.identifier.trdizinid380004
dc.identifier.urihttps://doi.org/10.15320/ICONARP.2018.60
dc.identifier.urihttps://search.trdizin.gov.tr/tr/yayin/detay/380004
dc.identifier.urihttps://hdl.handle.net/11480/15055
dc.identifier.volume6
dc.identifier.wosWOS:000454597000008
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakTR-Dizin
dc.language.isoen
dc.publisherSelcuk Univ
dc.relation.ispartofIconarp International Journal of Architecture and Planning
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_20241106
dc.subjectDeterioration
dc.subjectKonya
dc.subjectMisirlioglu Bridge
dc.subjectnon-destructive tests (NDT)
dc.subjectSille
dc.titleThe Determination of Deteriorations on The Misirlioglu Bridge (Konya, Turkey) by Non-Destructive Techniques (NDT)
dc.typeArticle

Dosyalar